Abstract
Background/AimThe efficacy and safety of carbon-ion radiotherapy (CIRT) for prostate cancer have already been demonstrated. The number of hemodialysis (HD) patients is increasing. Although the toxicity of CIRT in HD patients may be more severe, it has been insufficiently investigated. Therefore, we retrospectively analyzed the safety of CIRT for HD patients with prostate cancer in the present study.Materials and methodsFive HD patients with prostate cancer who underwent CIRT at the Kanagawa Cancer Center during November 2015-2020 were included in this study. CIRT was delivered by the raster scanning method (sCIRT). Adverse events were assessed using the Common Terminology Criteria for Adverse Events version 5.0. The dose-volume histogram (DVH) parameters of the target volume and normal organs were evaluated between initial planning computed tomography (CT) and in-room CT images.ResultsIn the acute phase, Grade 1 genitourinary toxicity was recorded in one patient. In the late phase, Grade 1 genitourinary toxicity was recorded in two patients. No gastrointestinal toxicities were noted during the follow-up period. In-room CT analysis revealed no significant differences among all DVH parameters of the target volume and normal organs when compared with the treatment plan dose.ConclusionsThe safety of sCIRT for prostate cancer in HD patients was investigated in the present study. In-room CT analysis suggested the robustness of the treatment plan. According to the present results, sCIRT for prostate cancer can be safely performed in HD patients.
Highlights
Radiotherapy (RT) is one of the definitive treatments for prostate cancer [1]
In-room computed tomography (CT) analysis revealed no significant differences among all dose-volume histogram (DVH) parameters of the target volume and normal organs when compared with the treatment plan dose
The safety of sCIRT for prostate cancer in HD patients was investigated in the present study
Summary
Five HD patients with prostate cancer who underwent CIRT at the Kanagawa Cancer Center during November 2015-2020 were included in this study. CIRT was delivered by the raster scanning method (sCIRT). Adverse events were assessed using the Common Terminology Criteria for Adverse Events version 5.0. The dose-volume histogram (DVH) parameters of the target volume and normal organs were evaluated between initial planning computed tomography (CT) and in-room CT images
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have