Abstract

The aim of this observational, longitudinal and retrospective study was to evaluate the fidelity of virtual surgical planning (VSP) performed on Dolphin Imaging & Management Solutions® 11.95 software on hard tissues, using the tools of the open-source software OrtogOnBlender - Blender3D. For this, linear, angular and 7-point anatomical measurements of the skeletal profile were used, and the discrepancies between the VSP and the result after bimaxillary orthognathic surgery were calculated. Pre- and postoperative cone beam CT (CBCT) scans of 43 consecutive patients with class II and III skeletal deformities were evaluated and the results of the VSP were compared to the 1-month postoperative results. All overlapping points presented values within the range considered clinically irrelevant (< 2 mm and < 4°) and differences were not significant (p > 0.05). The comparison of anatomical points showed lower values (≤ 2.11 mm) in point A of class II. For hard tissues, the comparison between VSP and 1-month postoperative tomography demonstrated the faithful results of virtual planning using this software.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.