Abstract
Timely and accurate detection of microclimates is extremely valuable for monitoring and stimulating exchanges of mass and energy in forest ecosystems under climate change. Recently, the rapid growth of wireless sensor networks (WSNs) has provided a new approach for detecting microclimates in a complex environment at multiple temporal and spatial scales. However, applications of wireless sensors in forest microclimate monitoring have rarely been studied, and the corresponding observation accuracy, error sources and correction methods are not well understood. In this study, through field experiments in two typical subtropical forest ecosystems in Zhejiang Province, China, the accuracy of the temperature and humidity observed by the wireless sensors was evaluated against standard meteorological data. Furthermore, the observation error sources were analyzed and corresponding correction models were established. The results showed that the wireless sensor-based temperature and humidity values performed well within the total observation accuracy. However, the observation errors varied with season, daily periodicity and weather conditions. For temperature, the wireless sensor observations were overestimated during the daytime while they were underestimated during the nighttime. For humidity, the data observed by the wireless sensors generally appeared as overestimates. Adopting humidity as the corrected factor, correction models were established and effectively improved the accuracy of the microclimatic data observed by the wireless sensors. Notably, our error analysis demonstrated that the observation errors may be associated with the shell material of the wireless sensor, suggesting that shading measures for the wireless sensors should be considered for outdoor work.
Highlights
The main means of monitoring forest microclimates is through in situ observations using a thermometer screen or auto weather station
The results showed that the wireless sensors generally performed well in terms of observation accuracy with slight overestimates
This study evaluated the accuracy of the temperature and humidity observed by wireless sensors in two typical subtropical forest ecosystems and further determined the sources of the observation error and established the corresponding correction models
Summary
The main means of monitoring forest microclimates is through in situ observations using a thermometer screen or auto weather station This approach usually ensures the observational accuracy of microclimatic variables. Wireless sensors are characterized by their low costs, high monitoring accuracy, flexible layouts and high-frequency continuous data[18,19] These advantages make detecting microclimatic variables in a complex ecosystem (e.g., forest ecosystem) possible[20,21]. Applications of wireless sensors for forest microclimate monitoring and the corresponding evaluations have been explored[4,25], the observational accuracy of the sensors, sources of observational bias and correction approaches are less understood[26,27,28]. Achieving these goals is beneficial to guiding sensor placement in forest ecosystem and provide a scientific basis for improving the designation and data correction of wireless sensors
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have