Abstract
We evaluated a new immunochromatographic assay (Legionella V-TesT, Coris BioConcept, Gembloux, Belgium) for its ability to detect Legionella pneumophila serogroup 1 antigen in urine. Test devices were read at various time points to determine the optimum incubation time regarding performance. The results were compared with those obtained with the BinaxNOW urinary antigen test. The sensitivity and specificity were 82.2% and 98.6%, respectively, for the Legionella V-TesT and 83.9% and 100%, respectively, for the BinaxNOW urinary antigen test after 15 min of incubation. When tests were examined after 60 min, the sensitivity for both tests increased to 91.5%.
Published Version
Talk to us