Abstract

The elution rate of leachables from ion exchange resin, which is used in condensate demineralizers and is one of several major sources of organic compounds in BWR cooling water, was measured. Properties of the leachables and elution rate depended on the kind of ion exchange resin and the years of use. The organic compounds elution rate of cation exchange resin was constant for 5 years and the molecular weight of these leachables was low. After 5 years, the elution rate increased and leachables consisted of organic compounds of high molecular weights of several thousand. The elution rate of anion exchange resin decreased yearly. The difference in the elution behavior was attributed to a dependence on oxidation degradation promoted by transition metal catalysis. The cation exchange resin included absorbed transition metal, while the anion exchange resin did not. An empirical formula showing the time dependence of the elution rate of organic compounds was derived. The formula was judged to be appropriate based on simulations of an actual BWR plant and comparisons of impurity concentrations with actual reactor water data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.