Abstract

An immobilized metal-ion affinity chromatography (IMAC) method has been developed and validated for the separation of copper complexing ligands from soil solution. We first investigated the retention behavior of simple model ligands on the IMAC column and found that the ability to form ternary complexes of the structure Cu–IDA–ligand was the dominant factor influencing ligand retention on the IMAC column. The log K value of the Cu-complex was found to have only a minor influence on the retention. Legends containing only carboxylic acid functional groups were not retained on the column. To optimize reproducibility and quantitative recovery of copper ligands from soil solution, different composition and pH values of eluting buffer were tested. Soil solution chromatograms exhibited one non-retained fraction and two retained fractions. The elution times of the retained fractions were characteristic of peptides and proteins (first peak) and for compounds containing aromatic amines (second peak). The results show that IMAC is an effective tool for the fractionation of copper complexing ligands that are capable of forming ternary complexes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.