Abstract

Aerosols formed during shooting events were studied with various techniques including the wide range size resolving sampling system Nano-ID(®) Select, followed by inductively coupled plasma mass spectrometry chemical analysis, scanning electron microscopy, and fast mobility particle sizing. The total lead mass aerosol concentration ranged from 2.2 to 72 µg m(-3). It was shown that the mass concentration of the most toxic compound lead is much lower than the total mass concentration. The deposition fraction in various compartments of the respiratory system was calculated using the ICRP lung deposition model. It was found that the deposition fraction in the alveolar range varies by a factor >3 for the various aerosols collected, depending on the aerosol size distribution and total aerosol concentration, demonstrating the importance of size resolved sampling in health risk evaluation. The proportion of the total mass of airborne particles deposited in the respiratory tract varies from 34 to 70%, with a median of 55.9%, suggesting the health risk based upon total mass significantly overestimates the accumulated dose and therefore the health risk. A comparison between conventional and so called 'green' ammunition confirmed significant lowering of concentrations of lead and other toxic metals like antimony in the atmosphere of indoor shooting ranges using 'green' ammunition, although higher concentrations of manganese and boron were measured. These metals are likely to be the constituents of new types of primers. They occur predominantly in the size fraction <250 nm of aerosols.