Abstract

To explore the clinical diagnostic efficacy of antineutrophil cytoplasmic antibody associated vasculitis (AAV) by comparing the consistency and coincidence rate of serum anti-myeloperoxidase (MPO) antibody and anti-protease 3 (PR3) antibody detected by digital liquid chip method (DLCM) and enzyme-linked immunosorbent assay (ELISA). To provide reference for the selection of detection methods of anti-MPO antibody and anti-PR3 antibody in clinical laboratory. This study is a cross-sectional study, a total of 307 cases of antineutrophil cytoplasmic antibodies were detected in the Department of Clinical Immunology, West China Hospital of Sichuan University from January to March 2021. The serum samples and related clinical information were collected. At the same time, the levels of anti-MPO antibody and anti-PR3 antibody in serum samples were detected by ELISA and DLCM, indirect immunofluorescence (IIF) was used to re-test the differential samples between the two methods. SPSS 26.0 was used to analyze the test results, Cohen's kappa coefficient analysis was used to compare the consistency of the two methods, and paired chi-square test was used to compare the sensitivity and specificity of the two methods to AAV. The results showed that the positive cases of anti-MPO antibody detected by ELISA and DLCM were 63 and 44, and the negative cases were 244 and 263; the positive cases of anti-PR3 antibody detected by ELISA and DLCM were 34 and 28, and the negative cases were 273 and 279. The results of anti-MPO antibody and anti-PR3 antibody detected by the two methods had good consistency and coincidence rate, in which the total coincidence rate of anti-MPO antibody was 92.51%, the positive coincidence rate was 66.67%, and the negative coincidence rate was 99.18%. The results of consistency analysis showed that kappa=0.741 had well consistency. The total coincidence rate of anti-PR3 antibody is 96.74%, the positive coincidence rate is 76.47%, and the negative coincidence rate is 99.27%. The consistency analysis results show that kappa=0.821 had strong consistency. The results of IIF re-test of differential samples showed that the coincidence rate between DLCM and IIF was higher. The results of comparative analysis of anti-MPO antibody and anti-PR3 antibody showed that the specificity of DLCM was better than that of ELISA, and its sensitivity was lower than that of ELISA. In conclusion, the results of anti-MPO antibody and anti-PR3 antibody detected by DLCM were consistent with those of ELISA. In the combined detection of anti-MPO antibody and anti-PR3 antibody, the specificity of DLCM is better than that of ELISA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.