Abstract

Delta-T Device Limited of Cambridge, UK have developed an integrated device which enables simultaneous measurement of horizontal global and diffuse irradiance as well as sunshine status at any given instance in time. To evaluate the performance of this new device, horizontal global and diffuse irradiance data were simultaneously collected from Delta-T device and Napier University's CIE First Class daylight monitoring station. To enable a cross check a Kipp & Zonen CM11 global irradiance sensor has also been installed in Currie, south-west Edinburgh. Sunshine duration data have been recorded at the Royal Botanical Garden, Edinburgh using their Campbell-Stokes recorder. Hourly data sets were analysed and plotted within the Microsoft Excel environment. Using the common statistical measures, Root Mean Square Difference (RMSD) and Mean Bias Difference (MBD) the accuracy of measurements of Delta-T sensor's horizontal global and diffuse irradiance, and sunshine duration were investigated. The results show a good performance on the part of Delta-T device for the measurement of global and diffuse irradiance. The sunshine measurements were found to have a lack of consistency and accuracy. It is argued herein that the distance between the respective sensors and the poor accuracy of Campbell-Stokes recorder may be contributing factors to this phenomenon.