Abstract
We recently reported a system for inactivating antineoplastics in which sodium hypochlorite is supplied by the electrolysis of sodium chloride solution. In this study, we designed an electrolysis apparatus for inactivating the cytotoxicity of antineoplastics in clinical wastewater using the system. The apparatus consists of an electrolysis cell with platinum–iridium electrodes, a pool tank, a circulating system for wastewater, a safety system for explosive gas and overflow, and an exhaust duct. The free chlorine concentration increased linearly up to 6500 mg l −1, and pH also increased to 9.0–10.0 within 2 h, when 0.9% sodium chloride solution was electrolyzed. We examined its efficacy with model and clinical wastewaters. The reciprocal of dilution factor for disappearance of cytotoxicity using Molt-4 cells was compared before and after electrolysis. In the model wastewater, that was 9.10 × 10 4 before electrolysis, and 3.56 × 10 2 after 2 h of electrolysis. In the clinical wastewater ( n = 26), that was 6.90 × 10 3–1.02 × 10 6 before electrolysis, and 1.08 × 10 2–1.45 × 10 4 after 2 h of electrolysis. Poisonous and explosive gases released by the electrolysis were measured; however, they were found to be negligible in terms of safety. The environmental load was evaluated by carbon dioxide generation as an index and it was found that the carbon dioxide generated by the electrolysis method was 1/70 lower than that by the dilution method with tap water. Moreover, the cost of the electrolysis method was 1/170 lower than that of the dilution method. This method was found to be both effective and economically valuable.