Abstract

The paper describes a practical method for real-time measurement of active power in a dielectric barrier discharge by calculating a Lissajous figures based on the Manley formula. Such a method is very useful for controlling the output ozone concentration in ozone generators taking into account the active power in a DBD reactor. A dielectric barrier discharge (DBD) in atmospheric pressure air was excited by a high-voltage pulse power supply. The active power of the reactor was estimated from the area of the Lissajous figure formed by the V-Q traces, which is directly proportional to the energy consumed per cycle at voltages of 8 and 12 kV, respectively.