Abstract
A software tool (EasyMDT) that measures temporal modulation detection thresholds of a broadband noise carrier is presented. EasyMDT is designed to be both easy and quick to promote the use in environments where testing time is limited, and testers may not have extensive technical expertise to use typical research software. In addition, by providing a standardized stimulus and protocol, data collected by all groups using the software can be compared directly. Details of EasyMDT, including a description of the protocol, stimuli, interface and how to obtain the software, are provided along with representative sample data from both normal-hearing listeners and cochlear implant (CI) users. Performance with the EasyMDT is compared with speech understanding metrics as well as a metric of spectral-temporal resolution. A "Full Curve" of modulation detection thresholds is measured using a three-interval forced-choice adaptive task in a single block for 7 modulation frequencies (10, 50, 75, 100, 150, 200, and 300 Hz). Similarly, the modulation detection thresholds were measured for only one modulation frequency in a block (either 100 Hz or 150 Hz). Modulation detection thresholds and block duration were recorded. In addition, performance on speech recognition tasks (CNC words, consonant identification, vowel identification, and AzBio sentences in noise) and a spectral-temporal resolution task (SMRT; Aronoff and Landsberger) were measured. Modulation detection thresholds were measured for both normal-hearing listeners and CI users. Only CI users participated in the speech and spectral-temporal tests. Modulation detection thresholds measured with EasyMDT were consistent with those previously reported from other laboratories. Modulation detection thresholds at a single modulation frequency (100 Hz or 150 Hz) were predictive of modulation detection thresholds measured as part of the Full Curve consisting of all 7 modulation frequencies. Testing durations for CI users dropped from an average of over 18 minutes for the Full Curve to under 3 minutes for either of the single modulation frequency measures. Modulation detection thresholds at 100 Hz correlated with CNC words, consonant identification, and AzBio sentences in noise, but not vowel identification. No correlations were found between modulation detection and spectral-temporal resolution. The EasyMDT is designed to be an easy-to-use tool that provides a nonlinguistic measure that can predict speech understanding. The test duration is short enough that it can be incorporated into clinical practice or as part of an experimental battery. The software is available for free download at https://www.ear-lab.org/software-downloads.html. The software is designed to have a minimum barrier of entry as well as provide a standardized protocol allowing direct comparison of modulation detection thresholds across studies and groups.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.