Abstract
Three-phase fluidized bed flotation column (TFC) is a new type of separation flotation method with high efficiency and low energy consumption. In this paper, the industrial experimental effect of TFC is investigated. The influence of operating parameters on the flotation separation effect was investigated by adjusting the operating parameters such as gas velocity, liquid velocity, and bed height. In addition, when the sampling depth and sampling radius are increased, the ash content in the selection zone increases with it. The relationship between the amount of mid-coal circulation and the ash content was also investigated. The ash content of refined coal gradually decreased from 10.28 % to 9.28 % when the amount of middle coal circulating was increased from 0 % to 50 % of the feed. This study explores the separation effect of TFC from industrial experiment perspective, which lays a good foundation for future industrial-scale applications.
Published Version
Talk to us