Abstract

In this paper, a scheme for how to utilize VFTLP (very fast transmission line pulse) data to design an input buffer circuit for CDM (charged-device model) ESD protection is reported. The impedance of the ESD device under VFTLP stress is nearly 120Ω at the beginning of turn-on transient, and decreases with time toward 10Ω prior to the voltage falling below 0V. In this work, the fact that the dynamic-characteristic impedance of the ESD device under VFTLP testing is independent of the stress current is found. Since both VFTLP zapping and the CDM are nanosecond events, the dynamic-characteristic impedance of the ESD device can be used to evaluate the CDM threshold voltage of the input buffer based on the equivalent and simplified RLC circuit.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.