Abstract

The aim of the present research study is to estimate the maximum permissible intrusive force mathematically with one-dimensional finite element method and to achieve the safe intrusion of a canine tooth without any damage to periodontal ligament (PDL). For this purpose, one-dimensional finite element (FE) model of a canine tooth was developed consisting of tooth (crown and root) and PDL structure. The maximum permissible intrusive force was computed mathematically. For this purpose, the maximum permissible stress was considered as ‘EPDL/1.5’, where ‘EPDL’ is the Young’s Modulus of PDL and factor of safety (FOS) is 1.5. The maximum permissible intrusive force was computed to be approximately 10 g-force (gf). For verification of this computed force value, finite element analysis was carried out on 3-dimensional canine tooth, PDL and bone structures for better verification and it is proved that 10 g-force (gf) value is safe without any damage to PDL tissues.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.