Abstract
Assessment of the lymphocyte doses is relevant for solving a number of radiobiological problems, including the risk assessment of hemoblastosis (leukemia, multiple myeloma, lymphoma etc.), as well as the use of circulating lymphocytes as “natural biodosimeters”. The latter is because the frequency of chromosomal aberrations occurring in lymphocytes following radiation exposure is proportional to the accumulated dose. Assessment of doses to the circulating lymphocytes requires due account of: first, the dose accumulated by the lymphocyte progenitors in the red bone marrow; and second, the dose accumulated during lymphocyte circulation through lymphoid organs. The models presented by International Commission on Radiological Protection (ICRP-67, ICRP-100) allow calculating the dose for specific lymphoid organs based on known level of radionuclide intakes. A recently developed model of circulating T-lymphocyte irradiation takes into account all sources of exposure and age-related dynamics of T-lymphocytes: (1) exposure of lymphocyte progenitors in red bone marrow: (2) exposure of T-lymphocytes in the lymphoid organs, taking into account the proportion of resident lymphocytes and the residence time of circulating lymphocytes in the specific lymphoid organs. The objective of the study is to assess the dose coefficients allowing for the transition from the ingestion of 141,144Ce, 95Zr, 103,106Ru, 95Nb to the doses accumulated in circulating T-lymphocytes. For calculations, we used the dose coefficients from ICRP publications for specific lymphoid organs, as well as published data on the residence time of circulating lymphocytes in lymphoid organs and tissues. As a result, it was shown that the doses in circulating T-lymphocytes are higher than those in the red bone marrow, but lower than the doses to the colon wall. The dose coefficients were age dependent; the maximum values were typical for newborns. The obtained dose coefficients for 141,144Ce, 95Zr, 95Nb and 103,106Ru can be used to estimate the tissue and organ doses based on data on the frequency of chromosomal aberrations in peripheral blood lymphocytes.
Highlights
Оценка дозы на лимфоциты при облучении человека представляет интерес в свете решения как минимум двух актуальных радиобиологических задач
DCs are shown for circulating T-lymphocytes, red bone marrow (RBM - white background), and large intestine]
This was done by Osgood (1954) in a theoretically impressive but purely speculative way, assuming a doubly overestimated lymphocyte volume, a fourfold overestimated number of bone marrow cells and a phantastic ratio of the lymphocytes in the lymphoid organs to the lymphocytes in the extralymphoid tissues of 1 : 10
Summary
Оценка доз облучения лимфоцитов при пероральном поступлении радионуклидов различной тропности. Оценка доз на циркулирующие лимфоциты требует учета двух факторов: во-первых, дозы, полученной предшественниками (прогениторами) лимфоцитов в красном костном мозге; а во-вторых, дозы, полученной лимфоцитами в лимфоидных органах при циркуляции. В последние годы была проведена большая работа для прояснения роли облучения прогениторов Т-клеток в ККМ и облучения циркулирую щ их Т-лимф оцитов во внескелетных лимфоидных тканях при формировании хромосомных аберраций [12]. Этот подход позво ляет рассчитывать дозы на Т-лимфоциты как средне взвешенное значение доз, формирующихся в ККМ при облучении Т-клеточных предшественников - прогениторов, а также в других лимфоидных тканях при миграции Т-лимфоцитов. Цель исследования - используя разработанную нами модель облучения Т-лимфоцитов, оценить дозовые коэффициенты, позволяющие перейти от перорально го поступления 141144Ce, 95Zr, 103106Ru, 95Nb к накопленной дозе на циркулирующие Т-лимфоциты
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.