Abstract
Estimation of local heat flux is challenging in a helical coil tube heat exchanger due to the complex flow field developed by tube curvature. The heat flux has uneven distribution in the angular direction of the tube cross-section. The current research aims to estimate the local heat flux at the fluid-solid interface for the turbulent flow of water in a helical coil tube by solving the inverse heat conduction problem (IHCP). Conjugate gradient method (CGM) with an adjoint problem is used as an inverse algorithm. First, the commercial CFD software ANSYS FLUENT is used for solving the governing equations of continuity, momentum, and energy for turbulent flow to obtain the heat flux at the fluid-solid interface. This heat flux is used to determine the temperature distribution at the outer surface of the tube. The heat flux is then considered unknown and it is estimated by CGM algorithm with the developed in-house code in MATLAB. The result shows that the estimation of heat flux by CGM is very accurate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.