Abstract
Live load-induced deformation is a significant evaluation index for bridge maintenance. To measure a structural displacement response, a method using several MEMS (Micro Electro Mechanical Systems) accelerometers has previously been developed. However, this method requires several sensors, and for improved practicality, a reduction in the number of sensors is desired. Therefore, in this article, a simple displacement monitoring method is proposed that uses only one MEMS accelerometer, which is installed at the longitudinal center of the target bridge. A wavelet transform-based method is applied to the acceleration records to identify the integration range for displacement estimation. The accuracy was evaluated on an actual in-service bridge. The result indicates high accuracy of displacement measurements, with only 5% error when compared with the values recorded by a contact displacement gauge.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.