Abstract

An ultrasensitive and broad-specific monoclonal antibody recognising cyproheptadine hydrochloride and six phenothiazines was produced. The 50% inhibition concentration against cyproheptadine hydrochloride was 0.036 ng/mL, and the cross-reactivities for six phenothiazines were from 6.33% to 63.16%. Based on the developed monoclonal antibody, an immunochromatographic strip was established, with the visual detection limits (cut-off values) of seven drugs ranging from 5 to 100 ng/g in feedstuffs. With the strip reader, the 50% inhibition concentration of the developed immunochromatographic strip for seven drugs ranged from 0.570 to 7.750 ng/g. The intra-assay recoveries were from 79.8% to 103.4% with the highest coefficient of variation of 11.3%. The inter-assay recoveries were from 79.0% to 96.6% with the highest coefficient of variation of 12.7%. In summary, the proposed immunochromatographic strip was considered suitable for simultaneously monitoring cyproheptadine hydrochloride and phenothiazines in feedstuffs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call