Abstract
An immunochromatography (ICG) strip test for rapid detection of atrazine in water samples was developed. A monoclonal antibody (MAb) specific to atrazine was produced from the cloned hybridoma cell (AT-1-M3) and used to develop a direct competitive enzyme-linked immunosorbent assay (DC-ELISA) and ICG strip. MAb conjugated to colloidal gold, and that was applied to the conjugate pad of the ICG strip. The visual detection limit for the ICG strip was 3 ng/mL. This test required only 10 min to get results and one step of sample to perform the assay. The results of water samples spiked with 5, 10, 20, and 50 ng/mL of atrazine by ICG strip were in good agreement with those obtained by DC-ELISA. The ICG strip was sufficiently sensitive and accurate to be useful for rapid screening of atrazine in various water samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.