Abstract

In order to establish an analytical model for the peak temperature within a sodium-water reaction jet, an analytical and theoretical investigation of an inert-hot-gas jet injected into a bath of cold liquid was performed as the first step. The laboratory study involved measurement of the centerline temperatures within hot N2-gas jets in water and in volatile refrigerant Suva-123. An integral two-fluid (gas+entrained drops) model of the submerged jet was developed in which a single, representative droplet size was employed to treat droplet-to-gas heat and mass exchange. Encouraging agreement with the measured centerline temperatures was obtained by using available information on jet entrainment coefficients. The centerline temperature measurements revealed that fine scale atomization of the entrained liquid occurs in the very near field of the jet and the mist so produced is entirely responsible for the downstream cooling of the submerged jet. The temperature measurements also revealed that water entered and penetrated the injector passage by a distance of about two injector diameters against an essentially sonic gas discharge flow (360 ms−1).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.