Abstract

A new method for industrial radiography is presented to assess image quality objectively. The assessment is performed by a modelled observer developed to interpret radiographic images in order to rate the detectability of structural defects. For the purpose of qualifying radiographic NDE procedures, computational tools simulate the image, but should additionally automatically assess the associated image quality instead of relying on human interpretation. The Channelized Hotelling Model Observer (CHO) approach, originally developed for medical imaging, is here developed for industrial NDE applications to measure objectively the defect's detectability. A validation study based on a comparison of the model's efficiency of observing circular and elongated flaws shows that the CHO outperforms other detectability models used by industry. Furthermore, the model's reliability was verified by comparing it to psychophysical data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.