Abstract

Over the last two decades, epicardial catheter ablation has evolved into a practical approach for treatment of ventricular tachycardia (VT). There are certain considerations when performing this procedure. First, presence of epicardial fat can diminish peak-to-peak electrogram amplitude and also impede radiofrequency energy delivery. Hence, epicardial VT ablation should be performed with cooled-tip radiofrequency using reduced irrigation flow within a relatively 'dry' pericardial milieu. Furthermore, catheter orientation is key when performing epicardial ablation. Lastly, hemo-pericardium remains the most common major adverse event of epicardial ablation and its presenting timeline may be used to identify the precise nature of this complication.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.