Abstract

Conformability, lightweight, consistency and low cost due to batch fabrication in situ on host structures are the attractive advantages of ultrasonic transducers made of piezoelectric polymer coatings for structural health monitoring (SHM). However, knowledge about the environmental impacts of piezoelectric polymer ultrasonic transducers is lacking, limiting their widespread use for SHM in industries. The purpose of this work is to evaluate whether direct-write transducers (DWTs) fabricated from piezoelectric polymer coatings can withstand various natural environmental impacts. The ultrasonic signals of the DWTs and properties of the piezoelectric polymer coatings fabricated in situ on the test coupons were evaluated during and after exposure to various environmental conditions, including high and low temperatures, icing, rain, humidity, and the salt fog test. Our experimental results and analyses showed that it is promising for the DWTs made of piezoelectric P(VDF-TrFE) polymer coating with an appropriate protective layer to pass various operational conditions according to US standards.