Abstract

The regenerator is a key component of a pulse tube cryocooler, and is also a major contributor to irreversibility and losses in the cryocooler. In this study a method for the assessment of losses in cryocooler regenerators based on entropy generation is proposed. Pore-level CFD simulations are performed for woven mesh regenerator filler by defining periodically repeating unit cells. Simulations are performed for steady-state (uni-directional) as well as periodic flows. It is shown that entropy generation in periodic flow is higher than in steady flow, and is sensitive to operating parameters as well as small geometric irregularities. It is proposed that by optimization of the microstructure of regenerator fillers the entropy generation and losses can be minimized.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.