Abstract

AbstractData on liquid entrainment are reported for rectangular‐cap bubble trays on 24‐in. tray spacing for an air‐water system. Several tray variations were studied, and entrainment is given for trays containing eight, twelve, and sixteen caps a tray. Some hydraulic characteristics (pressure drop, liquid backup, minimum vapor velocity, and downflow froth height) are also reported. It was found in this study that decreasing liquid path lenght increased the entrainment from a bubble‐cap tray and increasing tray bubbling area decreased entrainment. It was also found that decreasing slot area generally had no effect on liquid entrainment over the range investigated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.