Abstract

BackgroundHeavy metal pollution poses a serious threat to the ecological environment. Mercury ion (Hg2+) is a class of highly toxic heavy metal ions, which is bioaccumulative, difficult to breakdown, and has a significant affinity with sulfur and thiol-containing proteins, which seriously affects environmental safety and human health. Nanozyme-based sensing methods are expected to be used to detect toxic heavy metal ions. However, the application of precious metal nanozymes to develop portable sensors with simplicity, high stability, and high sensitivity has not been explored to a large extent. ResultsIn this paper, based on MXene's unique adsorption capacity for certain precious metal ions, PtNPs/Ti3C2TXNR composites were successfully prepared by in-situ growth of Pt nanoparticles (PtNPs) on the surface of Ti3C2TX MXene nanoribbons (Ti3C2TXNR) using the hydrothermal technique. Experimental data revealed PtNPs/Ti3C2TXNR exhibited superior peroxidase-like activity, attributed to the synergistic effect of well-dispersed ultrasmall PtNPs and electron transfer effect. Hg2+ can significantly inhibit enzyme-like activity of PtNPs/Ti3C2TXNR due to specific capture and partial in-situ reduction of PtNPs, so a colorimetric sensor was constructed for ultra-trace detection of Hg2+ with a linear range of 0.2 nM and 400 nM. Furthermore, using the portable detecting capabilities of smartphones and hydrogel, a smartphone-assisted hydrogel sensing platform of Hg2+ was constructed. Notably, the two-mode sensing platforms exhibited outstanding detection performance with LOD values as low as 15 pM (colorimetric) and 26 pM (hydrogel), respectively, superior to recently reported nanozyme-based Hg2+ sensors. SignificanceCompared with other methods, the PtNPs/Ti3C2TXNR-based dual-mode sensor designed in this paper has superior sensitivity, high selectivity, simple operation and portability. In particular, the dual-output sensing strategy enables self-confirmation of detection results, greatly improving the reliability of the sensor, and is expected to be used for the on-site determination of trace mercury ions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.