Abstract

The engineering design of the quasi-axisymmetric stellarator CHS-qa is described, having a toroidal period number of 2, major radius of 1.5 m, and plasma aspect ratio of 3.2. Although the entire structure of the machine is highly nonaxisymmetric and deformative, the following major engineering concerns for the modular coils and the vacuum vessel have been resolved: (a) modular coil design (curvature and twist of conductors), (b) supporting structures for modular coils, (c) errors due to electromagnetic forces and misalignment in manufacturing processes (analysis shows that the magnetic surface is robust against such disturbances), (d) construction procedure for vacuum vessel and modular coils, and (e) ports for heating and diagnostics.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.