Abstract

The energy flux to the ASDEX-Upgrade divertor plates is routinely measured by thermography and Langmuir probes. The thermographically observed power decay length at the target plate is about 1 cm near the inboard separatrix. During an edge localized mode (ELM) of type I the density profiles are significantly, changed; an additional contribution occurs characterized by a power decay length in the order of 10 cm outside the separatrix and additional power is deposited into the private flux region. It is supposed that this is due to the changing, contribution of energy conduction versus convection. Results of ELM-modelling using the coupled B2-EIRENE code reproduce the main features of the experimental observations. The sheath transmission factor is calculated by combining thermography and Langmuir probe data.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call