Abstract

The energy efficiency of hydraulic cylinder drives can be increased by replacing the actuator with a multi-chamber cylinder, utilising multiple supply lines with unique pressures or a combination of the concepts. Previous studies have demonstrated significant energy savings using a cascaded control system, which requires velocity feedback to stabilise the system. To avoid the need of position or velocity sensors in harsh conditions of mobile machines, this article presents a throttling control scheme, which achieves good energy efficiency on multi-pressure systems without velocity feedback. A simulation study was performed to determine the efficiency of the system, robustness against load variations and the effect of valve response time on performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.