Abstract

Data centers today account for up to 3% of all global electricity consumption and produce 200 million metric tons of . Hence, improving energy efficiency is an important operational concern. This article examines common operating practices such as server clustering, powering on/off, and bang–bang control in terms of energy efficiency. Extending the mixed integer programming (MIP) formulation in a previous research study, we introduce new constraints reflecting the operating practices adopted for operational convenience. We develop an algorithmic strategy for constructing energy efficient clusters of servers using two upper bounds on the cluster size. Numerical experiments show that server clustering and bang–bang control do not diminish energy efficiency, and that powering on/off by itself is insufficient. Our results produce a conclusion that differs from the published literature on data center design and operations. © 2017 Wiley Periodicals, Inc. NETWORKS, Vol. 71(2), 107–119 2018

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.