Abstract

Features of energy control centers in Japan are introduced from the following angles: (1) Configuration and function of computers in Load Dispatching Offices, taking two examples of different nature to compare design philosophy, function sharing and backup schemes, etc., (2) Relationship between Load Dispatching and Switching Operations, introducing two types of projects going on: (i) Centralized type in Chubu System where Load Dispatching and Switching Operations are issued in a unified hierarchy and (ii) Decentralized type in Kansai System where they are issued by two separate, but closely coupled, hierarchies, (3) Present status and future perspective of system operations from the security viewpoints.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.