Abstract

In this study, energy and exergy assessments of a perlite expansion furnace in a plaster factory are performed. Chemical properties of the perlite and its application areas are described. Energy and exergy relations according to the First and Second Law of Thermodynamics are derived. Energy and exergy efficiencies, losses and exergy destructions are calculated based on the measurements obtained from the system. Evaluations of environmental impact, energy management and economic are finally generalized according to the obtained results. Energy and exergy efficiencies of the furnace are determined to be 66% and 26%, respectively. Reference temperature effects on exergy efficiency, destruction and sustainability index are also presented. The results showed that the furnace has not been well designed in terms of thermal aspects due to high energy and exergy losses and the manufacturer producing the perlite expanded should establish an energy management structure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.