Abstract

In order to improve the economy of boiler soot blowing system, the steam source position of boiler soot blowing system should be optimized. For a 1000MW ultra-supercritical coal-fired unit, the thermodynamic process of soot blowing steam in temperature and pressure reducing station was studied through energy analysis and exergy analysis in this paper, and it was revealed that the annual water and energy consumption of boiler soot blowing system was independent of the steam source position, the change of steam source position only affected the annual exergy loss of soot blowing system. The comparion results indicated that the annual exergy loss of soot blowing system with cryogenic reheater outlet as steam source was minimal. After adopting cryogenic reheater outlet as the steam source position of soot blowing system, it would be more economical than the original soot blowing system with platen superheater outlet as steam source. The annual exergy loss would be reduced by about 2.183×1010kJ, and it was equivalent to an annual increase of power generation revenue by about 2486000CNY.