Abstract

Complex anatomical restrictions can lead to further interventions after the emergence of a postoperative aneurysm enlargement in thoracic endovascular aortic repair (TEVAR) for a thoracoabdominal aortic aneurysm (TAAA). A 75-year-old male underwent a TEVAR for a Crawford extent I TAAA. The main device and the distal extension were placed using a fenestrated technique, outside of the instructions for use. The aneurysm expanded because of an endoleak and stent graft migration; and was surgically repaired by fully salvaging the previous endografts 38 months after the first TEVAR. However, the distal extension, which was the proximal anastomosis site with a prosthetic graft, became completely dislocated from the main device eight months after the open surgical conversion, resulting again in the enlargement of the aneurysm. An additional TEVAR was successfully performed to correct the dislocated stent graft. An appropriate treatment strategy is crucial to prevent multiple reinterventions for TAAA with complex anatomical restrictions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.