Abstract

Methods to guide the surgical treatment of cancer utilizing handheld beta-sensitive probes in conjunction with tumor-avid radiopharmaceuticals [such as 18F-fluorodeoxyglucose (FDG)] have previously been developed. These technologies could also potentially be used to assist in minimally invasive techniques for the diagnosis of cancer. The goal of this project is to develop and test a system for performing radionuclide-guided endoscopies. This system (called Endoprobe) has four major subsystems: beta detector, position tracker, endoscope, and user interface. The beta detection unit utilizes two miniaturized solid state detectors to preferentially detect beta particles. The position tracking system allows real-time monitoring of the unit's location. The beta detector and position tracking system's receiver are mounted on the tip of an endoscope. Information from the beta detector and tracking system, in addition to the video signal from the endoscope, are combined and presented to the user via a computer interface. The system was tested in a simulated search for radiotracer-avid areas of esophageal cancer. The search for esophageal cancer was chosen because this type of cancer is often diagnosed with endoscopic procedures and has been reported to have good affinity for FDG. Accumulations of FDG in the normal organs of the abdomen were simulated by an anthropomorphic torso phantom filled with the appropriate amounts of radioactivity. A 1.5- mm-thick gelatin film containing FDG was used to simulate radiotracer uptake in the lining of normal esophagus. Esophageal lesions (both benign and malignant) were simulated by thin disks of gelatin (diameters=3.5-12 mm) containing appropriate concentrations of FDG embedded in the gelatin film simulating normal esophagus. Endoprobe facilitated visual identification and examination of the simulated lesions. The position tracking system permitted the location of the Endoprobe tip to be monitored and plotted in real time on a previously acquired positron emission tomography-computed tomography (PET-CT) image of the phantom. The detection system successfully acquired estimates of the beta flux emitted from areas chosen by the user. Indeed, Endoprobe was able to assist in distinguishing simulated FDG-avid areas as small as 3.5 mm in diameter from normal esophagus (p value <0.025). In addition to FDG, Endoprobe can be used with other positron or electron-emitting radionuclides such as IC or 131I. The next phase of this project will focus on modification of the prototype to make it more suitable for clinical use.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.