Abstract

A calcium carbonate suspension, encapsulated within particles of calcium alginate hydrogel, is proposed as a drug delivery device susceptible to ultrasound disruption. Spheres approximately 1mm in diameter were prepared by the coaxial airflow method from mixtures of 1% sodium alginate (m/v) and each of 50%, 75% and 100% calcium carbonate (m/v) in distilled water. This product was subjected to cycles of 85 Watt ultrasound in 1 second on/off bursts via a lab sonication system until fully disintegrated, a process requiring between 8 and 20 minutes depending upon initial calcium carbonate concentrations. The spheres subjected to vortex did not demonstrate any signs of mechanical degeneration after 30 minutes. Before use as a model implant, further work is required to develop a method of drying the particles to make them impermeable to drug diffusion before the time of their disruption with ultrasound.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call