Abstract

AbstractEmptying of an initially water-filled horizontal PVC pipeline driven by different upstream compressed air pressures and with different outflow restriction conditions, with motion of an air-water front through the pressurized pipeline, is investigated experimentally. Simple numerical modeling is used to interpret the results, especially the observed additional shortening of the moving full water column due to formation of a stratified water-air “tail.” Measured discharges, water-level changes, and pressure variations along the pipeline during emptying are compared using control volume (CV) model results. The CV model solutions for a nonstratified case are shown to be delayed as compared with the actual measured changes of flow rate, pressure, and water level. But by considering water-column mass loss due to the water-air tail and residual motion, the calibrated CV model yields solutions that are qualitatively in good agreement with the experimental results. A key interpretation is that the long air...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.