Abstract

In this work an alternative method for emittance determination based on pyrometric measurements is presented. The measurement procedure is limited by the spectral range of the infrared sensors used in this work (1400–5000 nm) and by its working temperature range (500–1000 °C). The measurement procedure has been applied to sintered SiC samples in the Plataforma Solar de Almería solar furnace SF40. The experimental results show that emittance decreases with increasing temperature and wavelength with a main value of 0.80. This behaviour is in agreement with experimental results obtained by other authors. Analysis of tests has revealed a good repeatability (1%) and accuracy (<3%) of this measurement procedure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.