Abstract
Objectives: To design a system capable of remotely measuring the Relative Humidity of the high voltage devices so that the risks involved with human physically interaction can be avoided, and the levels of humidity can be conveniently maintained at a remote location. Methods/Statistical Analysis: Variations in the humidity cause many major problems for human beings, electronic components, industrial machines etc. Hence to measure and maintain the humidity has become a nontrivial issue. However, in certain situations the manual methods of measuring humidity are not always convenient, in fact, hazardous. For instance, measuring and monitoring the humidity level of high voltage transformers can be very dangerous. The proposed system is the low cost and low complex implementation of embedded system and does not require Analog to Digital Conversion or vice versa to interface the Humidity sensing circuit with the microcontroller. The design provides the wireless transmission of the data, that makes easiness for the engineers (at industry) or for any other person (at home or any other place) to get humidity information of any remote and hazards locations. Findings: High power electrical devices such as transformers and transmission lines are severely affected by the humidity. Typically, the affordable levels of humidity are in the range of 45 to 65%. The rapid fluctuations in the levels of relative humidity can lead to a range of problems. The risks of physical damage, such as warping, cracking and splitting, chemical deterioration, and insect or mold attack are all increased when relative humidity is too high or too low. Also these fluctuations can damage collections that are experienced in many museums, galleries and libraries. Therefore, maintaining an appropriate level of humidity is imperative, as much as for hygienic reasons as well as for energy efficiency. Application / Improvement: The proposed design may find useful applications in Industries, agriculture fields, educational labs, Food storage places, Drying production industries, Blood banks, Coal mines, Sprinkler etc. Keywords: Humidity sensor HS1101, Microcontroller, Relative Humidity, RF Transmitter
Highlights
Humidity is the quantity of water which vaporizes in the air
Humidity is usually calculated as Relative Humidity (RH)
RH is a percentage that shows the amount of water vaporize in the air at a particular temperature matched to the maximum amount of water that is vaporize at the particular temperature is capable to hold without the water condensing
Summary
Humidity is the quantity of water which vaporizes in the air. RH is a percentage that shows the amount of water vaporize in the air at a particular temperature matched to the maximum amount of water that is vaporize at the particular temperature is capable to hold without the water condensing. The air at a set temperature comprises the entire vapor it can hold at that temperature, it takes a RH of 100 percent. If the humidity exceeds 100 percent, moisture will start to condense from the air. Measuring and monitoring the humidity level of high voltage transformers can be very dangerous. To solve this problem, we propose an embedded low cost solution of measuring humidity and wirelessly transmitting it to any remote location.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have