Abstract

This paper proposes the reduction of specific absorption rate (SAR) with shielding sheet is performed by the finite-difference time-domain method (FDTD) with Lossy-Drude model by CST Microwave Studio. We propose SAR evaluation and reduction methods based on power conservation. It has been shown that even though the use of shielding (ferrite) material not only reduces the SAR in the human head but also the radiated power, it reduces the SAR in head more considerably than the radiated power. Shielding materials have achieved a 58.68% reduction of the initial SAR value for the case of 1 gm SAR. These results suggest a guideline to choose various types of materials with the maximum SAR reducing effect for a phone model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.