Abstract

The feasibility of using ultrasound to enhance the elution of three ion exchange resins was investigated. A laboratory-scale elution column immersed in an ultrasonic bath was used to investigate three elution systems. XAD7–Au (eluted with NaOH, at a pH of 10), IR120H–Cd (eluted with HCl) and A375–SO 4 2− (eluted with saturated lime solutions). The physico-chemical stability of the resins was not affected adversely by sonication, with the exception of the XAD7 resin, which showed very slight degradation after prolonged exposure. Ultrasonic radiation improved the elution recoveries and kinetics considerably. This could possibly be attributed to an increase in counter-ion diffusive transport caused by acoustic vortex microstreaming, as well as the prevention of precipitation that can lead to the blockage of ion exchange sites.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.