Abstract
IntroductionElliptical-shaped humeral head prostheses have recently been proposed to reflect a more anatomic shoulder replacement. However, its subsequent effect on micro-motion of the glenoid component is still not understood.Materials and methodsSix fresh-frozen, cadaveric shoulders (mean age: 62.7 ± 9.2 years) were used for the study. Each specimen underwent total shoulder arthroplasty using an anatomic stemless implant. At 15°, 30°, 45° and 60° of glenohumeral abduction, 50° of internal and external rotations in the axial plane were alternatingly applied to the humerus with both an elliptical and spherical humeral head design. Glenohumeral translation was assessed by means of a 3-dimensional digitizer. Micro-motion of the glenoid component was evaluated using four high-resolution differential variable reluctance transducer strain gauges, placed at the anterior, posterior, superior, and inferior aspect of the glenoid component.ResultsThe elliptical head design showed significantly more micro-motion in total and at the superior aspect of glenoid component during external rotation at 15° (total: P = 0.004; superior: P = 0.004) and 30° (total: P = 0.045; superior: P = 0.033) of abduction when compared to the spherical design. However, during internal rotation, elliptical and spherical heads showed similar amounts of micro-motion at the glenoid component at all tested abduction angles. When looking at glenohumeral translation, elliptical and spherical heads showed similar anteroposterior and superoinferior translation as well as compound motion during external rotation at all tested abduction angles. During internal rotation, the elliptical design resulted in significantly more anteroposterior translation and compound motion at all abduction angles when compared to the spherical design (P < 0.05).ConclusionIn the setting of total shoulder arthroplasty, the elliptical head design demonstrated greater glenohumeral translation and micro-motion at the glenoid component during axial rotation when compared to the spherical design, potentially increasing the risk for glenoid loosening in the long term.Level of evidenceControlled Laboratory Study
Full Text
Topics from this Paper
Anteroposterior Translation
Internal Rotation
Glenohumeral Translation
Total Shoulder Arthroplasty
Glenoid Component
+ Show 5 more
Create a personalized feed of these topics
Get StartedTalk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
BMC Musculoskeletal Disorders
Mar 7, 2023
Archives of Orthopaedic and Trauma Surgery
Aug 31, 2020
Journal of clinical medicine
Jul 26, 2023
Journal of Shoulder and Elbow Surgery
Jun 1, 2019
Journal of Shoulder and Elbow Surgery
Sep 1, 2001
Journal of Bone and Joint Surgery
Oct 16, 2019
Journal of Shoulder and Elbow Surgery
Sep 1, 2022
Journal of Shoulder and Elbow Surgery
Mar 1, 2004
Clinical Orthopaedics & Related Research
Oct 1, 2017
Journal of Shoulder and Elbow Surgery
Jun 1, 2023
Journal of Shoulder and Elbow Surgery
Jun 1, 2023
Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association
Nov 24, 2021
Journal of Shoulder and Elbow Surgery
Jul 1, 2016
The American Journal of Sports Medicine
Jul 1, 2008
Kinesiology
Jan 1, 2018
Archives of Orthopaedic and Trauma Surgery
Archives of Orthopaedic and Trauma Surgery
Nov 25, 2023
Archives of Orthopaedic and Trauma Surgery
Nov 25, 2023
Archives of Orthopaedic and Trauma Surgery
Nov 25, 2023
Archives of Orthopaedic and Trauma Surgery
Nov 25, 2023
Archives of Orthopaedic and Trauma Surgery
Nov 24, 2023
Archives of Orthopaedic and Trauma Surgery
Nov 23, 2023
Archives of Orthopaedic and Trauma Surgery
Nov 23, 2023
Archives of Orthopaedic and Trauma Surgery
Nov 14, 2023
Archives of Orthopaedic and Trauma Surgery
Nov 11, 2023
Archives of Orthopaedic and Trauma Surgery
Nov 10, 2023