Abstract

The electrorheology of electrorheological (ER) fluids based on zeolite and silicone oil under dc fields was investigated at room temperature. ER fluids with volume fractions of 27% and 30% were prepared and tested. When a 5 kV/mm dc field was applied, shear yield stress of 26.7 kPa was obtained for the latter. The ER fluid with a higher volume fraction of zeolite had a higher current density and a higher shear yield stress under the same electric field. Compared with other ER fluids based on zeolite particles with low shear yield stress, the zeolite employed by us was found to have high dielectric constant and conductivity. The high permittivity mismatch and the high conductivity mismatch of the components of the fluids were considered responsible for the high shear yield stress.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.