Abstract

The polymerization of ferulic acid (poly-FA) on multi-walled carbon nanotubes (MWCNT) modified glassy carbon electrode was performed and the modified platform applied for the determination of NADH, epinephrine (EP) and dopamine (DA), one at a time. Cyclic voltammetry and chronoamperometry were employed to investigate the electrocatalytic oxidation of NADH, EP and DA on the modified electrode, in aqueous solutions. The obtained analytical curves for NADH, EP, and DA showed linear ranges between 59–1560, 73–1406, and 5–120μmolL−1, respectively. The detection limits were 17.7, 22.2 and 2.2μmolL−1 for NADH, EP and DA, respectively. The catalytic constant for the oxidation of NADH, EP and DA on the modified electrode were 5.56×103, 6.99×103 and 1.15×104Lmol−1s−1, respectively. The obtained versatile electrode was applied to the successful determination of EP, in epinephrine hydrochloride injection and DA in pharmaceutical samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.