Abstract

Environmental monitoring relies on compact, portable sensor systems capable of detecting pollutants in real-time. An integrated chemical sensor array system is developed for detection and identification of environmental pollutants in diesel and gasoline exhaust fumes. The system consists of a low noise floor analog front-end (AFE) followed by a signal processing stage. In this paper, we present techniques to detect, digitize, denoise and classify a certain set of analytes. The proposed AFE reads out the output of eight conductometric sensors and eight amperometric electrochemical sensors and achieves 91 dB SNR at 23.4 mW quiescent power consumption for all channels. We demonstrate signal denoising using a discrete wavelet transform based technique. Appropriate features are extracted from sensor data, and pattern classification methods are used to identify the analytes. Several existing pattern classification algorithms are used for analyte detection and the comparative results are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.