Abstract

We have studied electron-electron (e-e) interaction induced beam displacement in multiple electron beam systems both experimentally and using trajectory simulation. A prototype 32-beam lithography system was used to record the beam displacements on chrome mask plates and the latter were directly measured by electron microscopy. Both experimental data and simulation results of demagnifying columns were consistent with a demagnification of the electron beam array with increasing current. While the simulation matched qualitatively the experimental data well, it predicted a smaller effect than measured. The overall demagnification was underestimated by 20%–30%. In an attempt to understand the underlying physical reason, we used a phenomenological model for the e-e induced beam displacement to fit the acquired data. The analysis suggested that the trajectory simulation underestimated the defocusing lens effect of the interacting electrons by about 1.5. The parametric expression derived from this model may be used to correct for global space charge effects during multi-electron beam lithography.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.