Abstract

Permanent Magnet (PM) machines are favorable as an alternative to other machine topologies due to simpler construction and high torque density. However, it may result hight torque ripple due to an influence of cogging torque and electronic commutation. In this paper, comparisons of phase back-emf, static torque and cogging torque due to influence of tooth-tip asymmetry in 12-slot/10-pole double-layer and 12-slot/10-pole single layer winding machines are carried out using 2D Finite-Element Analysis. At rated condition, the stator asymmetry has great influence on the torque performance as there is significant reduction of torque ripple in 12-slot/10-pole mahine equipped with single layer winding than one equipped with double layer winding machine. It si confirmed that an optimum torque performance is desirable via stator iron modification in PM machines.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.