Abstract

This study compares the effectiveness of pollutant removal from synthetic dairy wastewater electrocoagulated by means of aluminum and iron anodic dissolution. A method based on the cubic function (third degree polynomial) was proposed for electrocoagulant dosing. Mathematical methods for calculating the optimal electrocoagulant doses proved to be quite precise and useful for practical applications. The results of gravimetric measurements of electrocoagulant (electrode) consumption demonstrated that theoretical doses of Al determined based on Faraday's law were substantially lower than those produced by electrode weighing. The above phenomenon was also discussed in the light of the results of polarization resistance measurements for Al and Fe electrodes used in the study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.