Abstract

A conducting polymer, polypyrrole, has been electrochemically synthesized from pyrrole monomer using cyclic voltammetry technique in aqueous solution in the presence of HDS dopant and KNO3 supporting electrolyte. The polymer was deposited on the surface of an Au-wire and the modified electrode obtained was then used as dodecylsulfate (DS-) ion sensor electrode. The best performance PPy-DS modified-Au electrode conditioned in the air system without HDS or SDS solution gave linear potential response for the concentration range of 1.0 x 10-5 - 1.0 x 10-3 M, sensitivity of 54.5 mV/decade, detection limit of 1.0 x 10-5 M, and response time of 23 - 30 second. The electrode showed good selectivity towards other anions, therefore can be used to determine SDS concentration in real samples system without any change of the samples matrix. Keywords: polypyrrole, SDS, cyclic voltammetry

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.